Outside Vacuum Sort Insulating Oil Purification Equipment &lparZYD-W-150&rpar
1&interval Increase breakdown voltage up to 75KV
2&interval Higher dehydration and degassing
Application&colon
Sequence ZYD CZPT-phase vacuum Transformer oil purifier equipment is special for dealing with the utilised and previous transformer oil&comma mutual oil&comma change oil&interval Evaluating with the single stage kind&comma this equipment adopts the double phases vacuum technique&comma which can improve the device functioning vacuum value hugely&comma so it can remove the h2o&comma gas and impurities in insulation oil higher-successfully&comma escalating the force force and good quality of oil&comma make confident the electrical system running properly&period of time Also it can inject the insulation oil into the transformers on line&comma regeneration the significantly deteriorated oil by taking away the polarity components&period The equipment is specifically applied to vacuum filling oil and drying for energy transmission equipments that are over 110KV&period
The oil complex info after treatment&colon
one&interval Gasoline content significantly less than &period1&percnt
two&interval Impurity measurement less than 1μ M CZPT totally free carbon
3&interval Oil dielectric energy &lparbreakdown voltage&rpar a lot more than 75KV
four&interval Acidity price considerably less than &period01 mgKOH&solg
five&period of time Dielectric decline aspects at 90° C less than &period001
Feature&colon
one&period PH of deal with oil &geq five&period5 2&time period Acid worth ≤ &period03mgkoH&solg
three&period of time Flash level &geq 145° C four&interval Anti-pressure&geq 75KV
five&time period Dielectric decline&colon Dielectric reduction&colon Tg δ &lpar90° C&rpar&percnt ≤ &period001
6&period Large vacuum&colon High level-vacuum ≤ 5Pa&semi Working-vacuum ≤ 35Pa
seven&time period Large absorption speed&colon Absorption pace electrical power &geq 333L&solSr&period
8&interval Duplex 3D stereo-evaporation&comma reducing the liquid water speedily
9&interval British isles G technologies&comma by which the trace drinking water that is demonstrate chain&comma this kind of as dissolved h2o&comma can be taken off successfully
ten&time period Instinctively removing impurities program filtering by means of the double FH trapezoidal community and absorbing by high polymer CZPT mechanical power
11&period of time Argon fiber infrared heating technique that can make the oil contain zero sum of ethyne soon after the remedy&period of time
If you have any interestedour devices&comma we will send out the appropriate oil purifier doc for your reference quickly&period of time
Optional&colon
A&interval With out enclosure&comma open up and stationary variety
B&period of time With enclosure&comma cubicle and stationary kind
C&period With skid foundation sort
D&interval Mounted in casters
E&time period Mounted on one-axle trailers &lparpneumatic tyre&comma velocity selectable&rpar
F&interval Mounted on double-axle trailers &lparpneumatic tyre&comma pace selectable&rpar
D&period of time PLC variety
You may possibly also be intrigued in&colon
A&period of time Transformer oil tester&comma screening the insulating oil’s CZPTctric power
B&time period Vacuum pumping set&comma pumping the transformer
C&period of time Moisture Meter&comma measuring the water content material in the transformer oil
D&period Movement Meter&comma measuring the flow oil amount via the equipment
Test products
1&period of time Transformer oil Breakdown voltage Tester &lpar BDV examination kit&rpar sequence IIJ-II
two&period Acidity tester design ACD-3000I
three&period of time Karl Fischer Water material Tester Model TP-6A &sol product TP-2100
four&period Totally automatic Interfacial Rigidity Analyzer model IT-800
five&period Fuel-Chromatography transformer oil fuel analyzer design DGA2013-1
six&period Kinematic Viscosity tester product VST-eight &solmodel VST-2000
seven&period of time Flash point tester &lparopen cup&rpar design TPO-3000
eight&period Flash point tester &lparclose cup&rpar design TPC-3000
9&interval TAN-DELTA TESTER&comma 10kV Capacitance and Dissipation Factor Test Set design CDEF
ten&time period CT&solPT tester product TPVA-404
eleven&time period Transformer switch ratio tester model HYG-II
twelve&interval Relaying Security Tester design TPJB-III
Parameters | Unit | ZYD-thirty | ZYD-50 | ZYD-one hundred | ZYD-one hundred fifty | ZYD-two hundred | ZYD-250 | ZYD-300 | |
Flow Rate | L&solH | 1800 | 3000 | 6000 | 9000 | 12000 | 15000 | 18000 | |
Working vacuum | MPa | -&period08 ~ -&period099 | |||||||
Working Pressure | MPa | ≤0&period3 | |||||||
Temperature Range | C | 20 ~ 80 | |||||||
Electrical power | Three Phase 50Hz&comma380V &lparor as needed&rpar | ||||||||
Working Noise | dB&lparA&rpar | 70 | 70 | 70 | seventy five | seventy five | 75 | 75 | |
Heating Power | kW | 28 | 30 | forty five | 60 | 75 | 90 | a hundred and twenty | |
Total Power | kW | 35&period5 | 37&period5 | fifty two&period5 | 71&period4 | 86&period5 | 102&period5 | 135 | |
Inlet&solOutlet | mm | φ25 | φ32 | φ42 | φ50 | φ50 | φ60 | φ60 | |
Excess weight | Kg | 600 | 800 | 1050 | 1400 | 1800 | 2000 | 2200 | |
All round | L | mm | 1050 | 1100 | 1200 | 1450 | 1600 | 1800 | 1900 |
W | mm | 750 | 800 | 950 | 950 | 1100 | 1200 | 1200 | |
H | mm | 1350 | 1400 | 1500 | 1650 | 1800 | 1900 | 1900 |