70mm2 Bare Copper Cable 70mm Copper Cable 70mm2 Power Cable

70mm2 Bare Copper Cable 70mm Copper Cable 70mm2 Power Cable

70mm2 bare copper cable/70mm copper cable/70mm2 power cable

Item Description

 

 

70mm2 bare copper cable/70mm copper cable/70mm2 power cable

 

 

 

  • Requirements: For flexing purposes

  • Outer jacket: PVC

  • Flame retardant

  • Silicone-totally free

  • Oil resistance: No oil resistance

  • Drag chain course: 3.1.one.1

Typical software regions:

  • For flexing purposes

  • With no impact of oil

  • If possible indoor applications

  • Especially for unsupported travels

  • Wooden/stone processing, packaging sector, supply systems, managing, changing gear

CZPT homes(CZPT Specification):

 

CZPT sheath bare copper single core cable: .5mm2, .75mm2, 1mm2, one.5mm2, 2.5mm2, 4mm2, 6mm2, 10mm2, 16mm2, 25mm2, 35mm2,
50mm2, 70mm2, 90mm2, 95mm2, 120mm2, 150mm2, 185mm2, 240mm2.

 

 

All specification and construction can be CZPTized according to customers’ need !

 

Dynamic data:

  • Min. bend radius, drag chain (issue): 15. x d

  • Min. bend radius, flexible (issue): 12. x d

  • Min. bend radius, fixed (factor): eight. x d

  • Temperature, drag chain min.: forty one °F ( 5 °C)

  • Temperature, drag chain max.: 158 °F (70 °C)

  • Temperature, versatile: 23 °F to +158 °F (-five °C to +70 °C) (subsequent DIN EN 60811-504)

  • Temperature, fastened: five °F to 158 °F (-fifteen °C to 70 °C) (pursuing DIN EN 50305)

  • v max., gliding: 10 ft/s (3 m/s)

  • a. max.: sixty five.6 ft/s² (twenty m/s²)

  • Size of travel: Travels up to 32.8 ft and much more (ten m and far more)

Cable construction:

  • Conductors: Conductor consisting of bare copper wires (in accordance to EN 65718).

  • Conductor insulation Mechanically large-top quality PVC combination.

  • Core construction Conductors cabled with an optimized pitch length.

  • Outer jacket Low-adhesion combination on the foundation of PVC, tailored to fit the requirements in drag chain.

  • Shade: Orange (related to RAL 2003)

 

CZPTal info:

  • Nominal voltage: 600/a thousand V (in accordance to DIN VDE 5718-3)

  • Testing voltage: four,000 V (subsequent DIN EN five 0571 )

Qualities and approvals:

  • Classification: Class 3.one.one.one
    three: Chain-ideal cables CZPT particular design (e.g. braiding in layers) for software in drag chains
    one: Unsupported
    one: No oil resistance
    one: no torsion

  • Oil resistance: No oil resistance

  • Flame retardant: According to IEC 60332-1-two, CEI 20-35, VW-one, FT-1

  • Silicone-cost-free: Free of charge from silicon which can have an effect on paint adhesion (according to PV 3.ten.7 – standing 1992).

  • UL/CSA: Style 15717, three hundred V, 80 °C

  • Lead cost-free: Adhering to 2011/sixty five/EU (RoHS-II)

  • CE: Pursuing 2014/35/EU

Guaranteed life time:

  • one million double strokes, min. bending issue at +5 °C/ +15°C and travel length ≤ 10 meter: seventeen.five x d

  • one million double strokes, min. bending factor at +fifteen °C/ +60°C and journey distance ≤ 10 meter: 15. x d

  • one million double strokes, min. bending factor at +60 °C/ +70°C and journey length ≤ 10 meter: 17.5 x d

  • three million double strokes, min. bending factor at +five °C/ +15°C and travel distance ≤ ten meter: 18.five x d

  • 3 million double strokes, min. bending aspect at +fifteen °C/ +60°C and travel distance ≤ 10 meter: sixteen. x d

  • three million double strokes, min. bending element at +sixty °C/ +70°C and vacation distance ≤ 10 meter: eighteen.5 x d

  • five million double strokes, min. bending factor at +five °C/ +15°C and journey distance ≤ 10 meter: 19.5 x d

  • 5 million double strokes, min. bending element at +fifteen °C/ +60°C and travel length ≤ ten meter: 17. x d

  • 5 million double strokes, min. bending element at +60 °C/ +70°C and travel length ≤ ten meter: 19.five x d

 

Make contact with:

 

 

70mm2 Bare Copper Cable 70mm Copper Cable 70mm2 Power Cable

Tags: