Z Series DC Motor
Electrical power: 55kw- 1600KW
Voltage: standard 400V, 440V, 660V
Pace: rated speed reference
Security Diploma: IP23/IP44
Insulation Class: F
Responsibility: S1
Bundle: export wood package
Payment: thirty% in progress, equilibrium by T/T or L/C at sight
Z355-4A, 200KW, 660V, 568r/min, IC06, IP23/IP44, F Insulation
CZPT
1. The strategies and security diploma of the motor
a) The approach of cooling of the motor is independently-cooled, according to GB/T1993 “Approach of cooling of rotating electrical machinery”, there are IC06, IC17, IC37, IC86W. CZPT entrance of cooling air is at the end of the main transmission(not the commutator side). The safety course of the motor can be divided into IP23 and IP44 according to the GB/T4942.1 and IEC34-5. If the person wants other method of cooling and defend course, it can be negotiated.
b) the relation in between the approach of cooling and the protection diploma of the motor pls see
Desk 1.
c) the cooling strategy, wind pressure, cooling water flux, motor electrical power see: Table two.
Frame |
Created-on blower |
air-to-water heat exchanger |
|||||
cooling wind |
Wind stress (whisht force) |
motor energy |
weight |
Cooling h2o flux |
motor electrical power |
bodyweight |
|
m³/hr |
Pa |
KW |
KG |
m³/hr |
KW |
KG |
|
H500 |
ten thousand |
1900 |
seven.five |
three hundred |
19 |
eleven |
900 |
H560 |
16500 |
2250 |
fifteen. |
400 |
22 |
eighteen.5 |
1100 |
H710 |
23500 |
2400 |
eighteen.five |
600 |
forty |
2*11 |
1600 |
two. The installation and the variety of motor according to the GB/T997 “the framework and set up sort of rotating electrical equipment”, have IM1001(Horizontal bottom set up, column biaxial) and IM1002 (Horizontal bottom install, column biaxial). If the person needs other types of set up construction, it have to be negotiated.
three. The placement of terminal box on regular motor is on the correct side when seeing from the main drive end. It can also be put in on the still left aspect, but it must be written in the buy deal.
4. The motor employing rolling bearing, nonstop introducing oil framework.
five. The motor can be installed the adhering to add-ons at the user’s alternative.
a) temperature detector ingredient can be set into stator winding and bearing room of two side, and hook up the outlet wire to the terminal box.
b) The non-drive party of the machine can equipped with tacho-generator, centrifugal starting up swap, coder and other individuals which construct up the velocity meter protecting unit.
c) Heater for avoiding condensation can be installed in the motor, but it have to be prepared in the other speak to
six. The air-to h2o warmth exchanger is normally set up on the top of the motor. If the user would like to be mounted on the side of the motor, the person should place CZPT it when buying and settle the assistant upholder by the user himself.
seven. The cooler equipped with wind stress switch, temperature controller, heater for stopping condensation and pther safeguard gadget.
Order notice
one. The motor type, power, voltage, running speed, excitation type, cooling type, number of output draft, position of outlet box, etc. Must be written when ordering.
2. Pls give clear indication of the accessory’s type, specification and number installed on the motor when ordering.
3. If the environment of using is special, humid torrid zone type motor is needed pls write “H” after the original type.
four. If you have some special requirement of the specification and technical requirement which is not listed in the booklet, pls contact us.
Packaging & Shipping and delivery
Tests Products